Input Specification:
| Input range: | 85-264 VAC |
| Frequency: | 47-63 Hz |
| Inrush current: | 38 A max., cold start @ 25°C |
| Efficiency | 65% typical at full load |
| EMI: |
FCC Class B conducted and radiated, CISPR 22 Class B conducted and radiated, EN55022 Class B conducted and radiated, VDE 0878 PT3 Class B conducted and radiated. |
| Power factor | 0.99 typical |
|
Safety ground leakage current |
<1 mA @ 50/60 Hz, 264 VAC input |
Output Specification:
| Maximum Power: |
70 W convection, 120 W with 30 CFM forced air |
| Adjustment range: | ±5% minimum on outputs one and two |
| Hold-up time: | 20 ms @ 120 W load, 120 VAC input |
| Overload protection: |
Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating |
| Overvoltage protection: |
3.3 V and 5 V output: 20% to 35% above nominal output |