Add to Cart
Input Specification
| Voltage adjustability: |
+5 V output on triples Vout on singles |
± 5.0% ± 5.0% |
|
Line regulation: LL to HL, FL |
Main output Auxiliary outputs |
± 0.2% ± 1.0% |
|
Load regulation: FL to NL |
Main output Auxiliary outputst |
± 2.0% ± 5.0% |
| Transient response: | +5 V (1.5 - 3 A) |
± 120 mV max. dev. 500 μs recovery |
| Temperature coefficient: | All outputs | ± 0.02%/°C |
| Overvoltage protection: | +5 V output | S3.15 A, 250 Vac In live and neutral |
| Output power limit: | Primary power limited | 90 W input power limit |
| Short circuit protection: |
Single outputs Multiple outputs |
Continuous Short term |
Output Specification
| Input voltage range: | Universal input |
85 - 264 Vac 120 - 370 Vdc |
| Input frequency range: | 47-440 Hz | |
| Max. input surge current: |
132 Vac, cold start 264 Vac, cold star |
12 A max. 24 A max. |
| Safety ground leakage current: |
110 Vac, 60 Hz 230 Vac, 50 Hz |
0.13 mA, max. 0.32 mA, max. |